Defibrillator

Model: SM-DE005

Key Specifications

Standard:Biphasic manual defibrillation/ECG/AED. Light Weight

Applied Departments

ICU& General Ward ER OR

Optional Features

  • SPO2
  • PACER

Product Details

Display

Display Type: 8 inches High-resolution LCD display.

Sweep Speed: 25mm/sec.

Information: Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

 

Defibrillator

Waveform: Biphasic

Charge Time: Less than 7 seconds with a new fully charged battery.

Energy Display: Monitor display indicates both selected and delivered energy.

Charge Prompt Type: Voice and visual prompts.

Electrode Impedance Measurement Range: 0-250 ohms.

 

AED Mode

AED Function: Auto analyzes and charges x3 with programmable auto energy level selection, screen prompts, and voice prompts.

Shockable Rhythms: Ventricular fibrillation with amplitude≥200UV, Ventricular tachycardia with rates≥140bpm, and QRS complex wave duration≥140ms.

Charge Control: Control on device front panel, press key on paddle.

Prompts: Voice and visual prompts.

 

Manual Mode

Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 Joules.

Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor.

 

ECG Monitoring

Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.

Lead Selection: Displayed on monitor, paddles, l, II, III, AVR, AVL, AVF, V.

ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.

Heart Rate: 20-300BPM.

Heart Rate Alarm: On/Off displayed on monitor, user-selectable.

Smart Alarms: Beeper/Voice prompts indicate shockable rhythm.

 

SpO2 Module

Measurement Range: 30-100%, +2% between 80%-90%, others + 5%

Alarm Range: User set high limit and low limit

Alarm Accuracy: +10% within setting values

Alarm Time Accuracy: Less than 12 sec

 

Recorder

Paper: 50mm thermal.

Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.

Printing Method: High-resolution, thermal array print head.

Print-out Modes: Manual or automatic, user-configurable.

On/Off Control: Front panel and paddle.

Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

 

Battery

Type: Rechargeable, Ni-MH battery, 12V.

Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 5 hours maximum of continuous ECG monitoring.

Additional parameters will affect operating time with different functions.